automation-suite
2022.10
false
- Overview
- Requirements
- Installation
- Q&A: Deployment templates
- Downloading the installation packages
- Install-uipath.sh Parameters
- Enabling Redis High Availability Add-On for the cluster
- Document Understanding configuration file
- Adding a dedicated agent node with GPU support
- Connecting Task Mining application
- Adding a dedicated agent Node for Task Mining
- Adding a Dedicated Agent Node for Automation Suite Robots
- Post-installation
- Cluster administration
- Monitoring and alerting
- Migration and upgrade
- Migration options
- Step 1: Moving the Identity organization data from standalone to Automation Suite
- Step 2: Restoring the standalone product database
- Step 3: Backing up the platform database in Automation Suite
- Step 4: Merging organizations in Automation Suite
- Step 5: Updating the migrated product connection strings
- Step 6: Migrating standalone Insights
- Step 7: Deleting the default tenant
- B) Single tenant migration
- Product-specific configuration
- Best practices and maintenance
- Troubleshooting
- How to troubleshoot services during installation
- How to uninstall the cluster
- How to clean up offline artifacts to improve disk space
- How to clear Redis data
- How to enable Istio logging
- How to manually clean up logs
- How to clean up old logs stored in the sf-logs bucket
- How to disable streaming logs for AI Center
- How to debug failed Automation Suite installations
- How to delete images from the old installer after upgrade
- How to automatically clean up Longhorn snapshots
- How to disable TX checksum offloading
- How to address weak ciphers in TLS 1.2
- Unable to run an offline installation on RHEL 8.4 OS
- Error in Downloading the Bundle
- Offline installation fails because of missing binary
- Certificate issue in offline installation
- First installation fails during Longhorn setup
- SQL connection string validation error
- Prerequisite check for selinux iscsid module fails
- Azure disk not marked as SSD
- Failure after certificate update
- Antivirus causes installation issues
- Automation Suite not working after OS upgrade
- Automation Suite requires backlog_wait_time to be set to 0
- Volume unable to mount due to not being ready for workloads
- Unable to launch Automation Hub and Apps with proxy setup
- Failure to upload or download data in objectstore
- PVC resize does not heal Ceph
- Failure to resize PVC
- Failure to resize objectstore PVC
- Rook Ceph or Looker pod stuck in Init state
- StatefulSet volume attachment error
- Failure to create persistent volumes
- Storage reclamation patch
- Backup failed due to TooManySnapshots error
- All Longhorn replicas are faulted
- Setting a timeout interval for the management portals
- Update the underlying directory connections
- Authentication not working after migration
- Kinit: Cannot find KDC for realm <AD Domain> while getting initial credentials
- Kinit: Keytab contains no suitable keys for *** while getting initial credentials
- GSSAPI operation failed due to invalid status code
- Alarm received for failed Kerberos-tgt-update job
- SSPI provider: Server not found in Kerberos database
- Login failed for AD user due to disabled account
- ArgoCD login failed
- Failure to get the sandbox image
- Pods not showing in ArgoCD UI
- Redis probe failure
- RKE2 server fails to start
- Secret not found in UiPath namespace
- ArgoCD goes into progressing state after first installation
- Unexpected inconsistency; run fsck manually
- MongoDB pods in CrashLoopBackOff or pending PVC provisioning after deletion
- MongoDB Pod Fails to Upgrade From 4.4.4-ent to 5.0.7-ent
- Unhealthy services after cluster restore or rollback
- Pods stuck in Init:0/X
- Prometheus in CrashloopBackoff state with out-of-memory (OOM) error
- Missing Ceph-rook metrics from monitoring dashboards
- Pods cannot communicate with FQDN in a proxy environment
- Navigating to Insights homepage generates a 404
- Looker fails to initialize
- Using the Automation Suite Diagnostics Tool
- Using the Automation Suite support bundle
- Exploring Logs
Looker fails to initialize
Automation Suite Installation Guide
Last updated Dec 16, 2024
Looker fails to initialize
During Looker initialization, you might encounter and error stating
RuntimeError: Error starting Looker
. A Looker pod failure produced this error due to a possible system failure or loss of power. The issue is persistent even
if you reinitialize Looker.
To solve this issue, delete the persistent volume claim (PVC) and then restart.