automation-suite
2022.10
false
UiPath logo, featuring letters U and I in white

Automation Suite Installation Guide

Last updated Dec 16, 2024

Automation Suite requires backlog_wait_time to be set to 0

Description

Audit events can cause instability (system freeze) if backlog_wait_time is not set to 0.

Solution

If the installer fails with the Automation Suite requires backlog_wait_time to be set 0 error message, take the following steps to set backlog_wait_time to 0.
  1. Set backlog_wait_time to 0 by appending --backlog_wait_time 0 in the /etc/audit/rules.d/audit.rules file.
  2. Reboot the node.
  3. Validate if backlog_wait_time value is set to 0 for auditctl by running sudo auditctl -s | grep "backlog_wait_time" in the node.