automation-suite
2022.10
false
- Overview
- Requirements
- Installation
- Q&A: Deployment templates
- Downloading the installation packages
- Install-uipath.sh Parameters
- Enabling Redis High Availability Add-On for the cluster
- Document Understanding configuration file
- Adding a dedicated agent node with GPU support
- Connecting Task Mining application
- Adding a dedicated agent Node for Task Mining
- Adding a Dedicated Agent Node for Automation Suite Robots
- Post-installation
- Cluster administration
- Monitoring and alerting
- Migration and upgrade
- Migration options
- Step 1: Moving the Identity organization data from standalone to Automation Suite
- Step 2: Restoring the standalone product database
- Step 3: Backing up the platform database in Automation Suite
- Step 4: Merging organizations in Automation Suite
- Step 5: Updating the migrated product connection strings
- Step 6: Migrating standalone Insights
- Step 7: Deleting the default tenant
- B) Single tenant migration
- Product-specific configuration
- Best practices and maintenance
- Troubleshooting
- How to troubleshoot services during installation
- How to uninstall the cluster
- How to clean up offline artifacts to improve disk space
- How to clear Redis data
- How to enable Istio logging
- How to manually clean up logs
- How to clean up old logs stored in the sf-logs bundle
- How to disable streaming logs for AI Center
- How to debug failed Automation Suite installations
- How to delete images from the old installer after upgrade
- How to automatically clean up Longhorn snapshots
- How to disable TX checksum offloading
- How to address weak ciphers in TLS 1.2
- Unable to run an offline installation on RHEL 8.4 OS
- Error in Downloading the Bundle
- Offline installation fails because of missing binary
- Certificate issue in offline installation
- First installation fails during Longhorn setup
- SQL connection string validation error
- Prerequisite check for selinux iscsid module fails
- Azure disk not marked as SSD
- Failure after certificate update
- Antivirus causes installation issues
- Automation Suite not working after OS upgrade
- Automation Suite requires backlog_wait_time to be set to 0
- Volume unable to mount due to not being ready for workloads
- Unable to launch Automation Hub and Apps with proxy setup
- Cluster unhealthy after automated upgrade from 2021.10
- Upgrade fails due to unhealthy Ceph
- RKE2 not getting started due to space issue
- SQL validation fails during upgrade
- Failure to upload or download data in objectstore
- PVC resize does not heal Ceph
- Failure to resize PVC
- Failure to resize objectstore PVC
- Rook Ceph or Looker pod stuck in Init state
- StatefulSet volume attachment error
- Failure to create persistent volumes
- Storage reclamation patch
- Backup failed due to TooManySnapshots error
- All Longhorn replicas are faulted
- Setting a timeout interval for the management portals
- Update the underlying directory connections
- Authentication not working after migration
- Kinit: Cannot find KDC for realm <AD Domain> while getting initial credentials
- Kinit: Keytab contains no suitable keys for *** while getting initial credentials
- GSSAPI operation failed due to invalid status code
- Alarm received for failed Kerberos-tgt-update job
- SSPI provider: Server not found in Kerberos database
- Login failed for AD user due to disabled account
- ArgoCD login failed
- Failure to get the sandbox image
- Pods not showing in ArgoCD UI
- Redis probe failure
- RKE2 server fails to start
- Secret not found in UiPath namespace
- ArgoCD goes into progressing state after first installation
- Unexpected inconsistency; run fsck manually
- MongoDB pods in CrashLoopBackOff or pending PVC provisioning after deletion
- MongoDB Pod Fails to Upgrade From 4.4.4-ent to 5.0.7-ent
- Unhealthy services after cluster restore or rollback
- Pods stuck in Init:0/X
- Prometheus in CrashloopBackoff state with out-of-memory (OOM) error
- Missing Ceph-rook metrics from monitoring dashboards
- Using the Automation Suite Diagnostics Tool
- Using the Automation Suite Support Bundle Tool
- Exploring Logs
SQL validation fails during upgrade
Automation Suite Installation Guide
Last updated Oct 4, 2024
SQL validation fails during upgrade
When trying to upgrade to a new Automation Suite version,
validateUiPathASReadiness.sh
can fail to validate SQL connectivity.
The
validateUiPathASReadiness.sh
script uses the podman
command to run containers to verify the SQL connection.
If there is any corruption in the Podman system data, the
podman
command can fail to run and, consequently, can cause the validateUiPathASReadiness.sh
execution to fail also.
You can verify if there is any Podman data corruption by running the
podman volume ls
or podman secret ls
command. If the previous commands fail, you can reset the Podman files by running the podman system reset
command.
Note:
The
podman system reset
command stops all Podman containers and removes all images, volumes, networks, and container content.