Automation Suite
2022.10
false
- Overview
- Requirements
- Installation
- Q&A: Deployment templates
- Downloading the installation packages
- Install-uipath.sh Parameters
- Enabling Redis High Availability Add-On for the cluster
- Document Understanding configuration file
- Adding a dedicated agent node with GPU support
- Connecting Task Mining application
- Adding a dedicated agent Node for Task Mining
- Adding a Dedicated Agent Node for Automation Suite Robots
- Post-installation
- Cluster administration
- Monitoring and alerting
- Migration and upgrade
- Migration options
- Step 1: Moving the Identity organization data from standalone to Automation Suite
- Step 2: Restoring the standalone product database
- Step 3: Backing up the platform database in Automation Suite
- Step 4: Merging organizations in Automation Suite
- Step 5: Updating the migrated product connection strings
- Step 6: Migrating standalone Insights
- Step 7: Deleting the default tenant
- B) Single tenant migration
- Product-specific configuration
- Best practices and maintenance
- Troubleshooting
- How to troubleshoot services during installation
- How to uninstall the cluster
- How to clean up offline artifacts to improve disk space
- How to clear Redis data
- How to enable Istio logging
- How to manually clean up logs
- How to clean up old logs stored in the sf-logs bundle
- How to disable streaming logs for AI Center
- How to debug failed Automation Suite installations
- How to delete images from the old installer after upgrade
- How to automatically clean up Longhorn snapshots
- How to disable NIC checksum offloading
- Unable to run an offline installation on RHEL 8.4 OS
- Error in Downloading the Bundle
- Offline installation fails because of missing binary
- Certificate issue in offline installation
- First installation fails during Longhorn setup
- SQL connection string validation error
- Prerequisite check for selinux iscsid module fails
- Azure disk not marked as SSD
- Failure after certificate update
- Antivirus causes installation issues
- Automation Suite not working after OS upgrade
- Automation Suite requires backlog_wait_time to be set to 0
- Volume unable to mount due to not being ready for workloads
- Unable to launch Automation Hub and Apps with proxy setup
- Failure to upload or download data in objectstore
- PVC resize does not heal Ceph
- Failure to resize PVC
- Failure to resize objectstore PVC
- Rook Ceph or Looker pod stuck in Init state
- StatefulSet volume attachment error
- Failure to create persistent volumes
- Storage reclamation patch
- Backup failed due to TooManySnapshots error
- All Longhorn replicas are faulted
- Setting a timeout interval for the management portals
- Update the underlying directory connections
- Authentication not working after migration
- Kinit: Cannot find KDC for realm <AD Domain> while getting initial credentials
- Kinit: Keytab contains no suitable keys for *** while getting initial credentials
- GSSAPI operation failed due to invalid status code
- Alarm received for failed Kerberos-tgt-update job
- SSPI provider: Server not found in Kerberos database
- Login failed for AD user due to disabled account
- ArgoCD login failed
- Failure to get the sandbox image
- Pods not showing in ArgoCD UI
- Redis probe failure
- RKE2 server fails to start
- Secret not found in UiPath namespace
- ArgoCD goes into progressing state after first installation
- Unexpected inconsistency; run fsck manually
- MongoDB pods in CrashLoopBackOff or pending PVC provisioning after deletion
- MongoDB Pod Fails to Upgrade From 4.4.4-ent to 5.0.7-ent
- Unhealthy services after cluster restore or rollback
- Pods stuck in Init:0/X
- Prometheus in CrashloopBackoff state with out-of-memory (OOM) error
- Missing Ceph-rook metrics from monitoring dashboards
- Using the Automation Suite Diagnostics Tool
- Using the Automation Suite Support Bundle Tool
- Exploring Logs
How to debug failed Automation Suite installations
Automation Suite Installation Guide
Last updated Apr 24, 2024
How to debug failed Automation Suite installations
If the Automation Suite installation fails while running the
installUiPathAS.sh
or install-uipath.sh
installers, take the following steps to debug it:
- Check if the nodes are active.
- For server nodes, run
sudo systemctl status rke2-server
. - For agent nodes, run
sudo systemctl status rke2-agent
.- If the nodes are active, but the installation failed, use the diagnostic tool to troubleshoot.
- If a node is inactive, check the installation logs for any errors.
- For server nodes, run
-
Capture basic installation logs.
The installer prints the installation log location when usinginstallUiPathAS.sh
. Forinstall-uipath.sh
, logs are stored in the directory from where the installation command was executed.If the installation logs do not reveal the issue, run the installers in debug mode for more details. For both online and offline installations, runinstall-uipath.sh -d
. The-d
flag runs the installer in debug mode.Troubleshooting can also be done based on the logs available in ArgoCD, Istio, or on the machine itself. For more details, see Exploring logs.
-
Capture all installation logs.
To capture all logs related to the Automation Suite installation, download the
rke2logCollector.sh
script from GitHub and run it under the root account.The script collects the following data:
- system info
- network info
- docker info
- k3s info
- rke2 info
- rancher logs
- k8s component logs
- system pod logs
- nginx-proxy info
- k3s cluster logs
- system pod logs
- rke2 cluster logs
- rke2 system pod logs
- rke2 agent/server logs
- system logs from /var/log
- system logs from journald
- k8s directory state
- k8s certificates
- k3s directory state
- k3s certificates
- k3s server certificates
- rke2 directory state
- rke2 certificates
- rke2 server certificates
- rke etcd info
- etcdctl output
- rke2 etcd info