Automation Suite
2022.4
false
Banner background image
Automation Suite Installation Guide
Last updated Apr 24, 2024

RKE2 Server Fails to Start

Description

The server fails to start. There are a few different reasons for RKE2 not starting properly, which are usually found in the logs.

Solution

Check the logs using the following commands:

journalctl -u rke2-serverjournalctl -u rke2-server

Possible reasons (based on logs): too many learner members in cluster

Too many etcd servers are added to the cluster, and there are two learner nodes trying to be promoted. More information here: Runtime reconfiguration.

Perform the following:

  1. Under normal circumstances, the node should become a full member if enough time is allowed.
  2. An uninstall-reinstall cycle can be attempted.

Alternatively, this could be caused by a networking problem. Ensure you have configured the machine to enable the necessary ports.

  • Description
  • Solution

Was this page helpful?

Get The Help You Need
Learning RPA - Automation Courses
UiPath Community Forum
Uipath Logo White
Trust and Security
© 2005-2024 UiPath. All rights reserved.