RKE2 fails during installation and upgrade

Description

Occasionally, when performing a clean installation or upgrade to Automation Suite 2022.4.11, you may encounter a restart issue disrupting RKE2. This issue usually causes the rke2-server service to enter a failed state.

docs image

To verify if you are affected by this specific issue, run the following command to get a more detailed error message:

journalctl -xe -u rke2-server cmdjournalctl -xe -u rke2-server cmd

You should get the following error message:

docs image
docs image

Solution

To fix the issue, take the following steps:

  1. Manually restart the rke2-server multiple times until it successfully starts.

    systemctl restart rke2-serversystemctl restart rke2-server
  2. Verify the status of the rek2-server service. If the outcome indicates that the service is active, then the issue has been resolved.

    systemctl status rke2-server and ifsystemctl status rke2-server and if