activities
latest
false
UiPath logo, featuring letters U and I in white
UI Automation Activities
Last updated Nov 22, 2024

Get URL

UiPath.UIAutomationNext.Activities.NGetUrl

Description

Retrieves the URL from the current web page.

This activity must be added inside a Use Application/Browser activity.

To use this activity outside a Use Application/Browser activity, you need to provide an Input element.

Project compatibility

Windows - Legacy | Windows | Cross-platform

Windows - Legacy, Windows configuration

Designer panel
  • Save to - The String variable in which you want to store the retrieved URL.
Properties panel

Common

  • Continue on error - Specifies if the automation should continue even when the activity throws an error. This field only supports Boolean values (True, False). The default value is False. As a result, if the field is blank and an error is thrown, the execution of the project stops. If the value is set to True, the execution of the project continues regardless of any error.
  • Delay after - Delay (in seconds) between the time this activity is completed and the time the next activity begins any operations. The default value is 0.3 seconds. Adding a delay between activities ensures that one activity has enough time to complete before the next activity begins.

  • Delay before - Delay (in seconds) between the time the previous activity is completed and the time this activity begins performing any operations. The default value is 0.2 seconds. Adding a delay between activities ensures that one activity has enough time to complete before the next activity begins.

  • Display name - The name displayed for the activity in the Designer panel. A display name is automatically generated when you indicate a target.

  • Timeout - Specify the amount of time (in seconds) to wait for the activity to be executed before throwing an error. The default value is 30 seconds.

Misc

  • Private - If selected, the values of variables and arguments are no longer logged at Verbose level. This field supports only Boolean (True, False) values. The default value is False.

Output

  • Current URL - See Save to in the Designer panel.

Cross-platform configuration

  • Save to1/ URL2 - The String variable in which you want to store the retrieved URL.

    1 - property name in Studio Desktop

    2 - property name in Studio Web

Additional options

Timings

  • Delay before - Delay (in seconds) between the time the previous activity is completed and the time this activity begins performing any operations. The default value is 0.2 seconds. Adding a delay between activities ensures that one activity has enough time to complete before the next activity begins.

  • Delay after - Delay (in seconds) between the time this activity is completed and the time the next activity begins any operations. The default value is 0.3 seconds. Adding a delay between activities ensures that one activity has enough time to complete before the next activity begins.

  • Timeout - Specify the amount of time (in seconds) to wait for the activity to be executed before throwing an error. The default value is 30 seconds.

  • Continue on error - Specifies if the automation should continue even when the activity throws an error. This field only supports Boolean values (True, False). The default value is False. As a result, if the field is blank and an error is thrown, the execution of the project stops. If the value is set to True, the execution of the project continues regardless of any error.

Was this page helpful?

Get The Help You Need
Learning RPA - Automation Courses
UiPath Community Forum
Uipath Logo White
Trust and Security
© 2005-2024 UiPath. All rights reserved.