- Getting Started
- Setup and Configuration
- Automation Projects
- Dependencies
- Types of Workflows
- Control Flow
- File Comparison
- Automation Best Practices
- Source Control Integration
- Debugging
- Logging
- The Diagnostic Tool
- Workflow Analyzer
- About Workflow Analyzer
- ST-NMG-001 - Variables Naming Convention
- ST-NMG-002 - Arguments Naming Convention
- ST-NMG-004 - Display Name Duplication
- ST-NMG-005 - Variable Overrides Variable
- ST-NMG-006 - Variable Overrides Argument
- ST-NMG-008 - Variable Length Exceeded
- ST-NMG-009 - Prefix Datatable Variables
- ST-NMG-011 - Prefix Datatable Arguments
- ST-NMG-012 - Argument Default Values
- ST-NMG-016 - Argument Length Exceeded
- ST-NMG-017 - Class name matches default namespace
- ST-DBP-002 - High Arguments Count
- ST-DBP-003 - Empty Catch Block
- ST-DBP-007 - Multiple Flowchart Layers
- ST-DPB-010 - Multiple instances of [Workflow] or [Test Case]
- ST-DBP-020 - Undefined Output Properties
- ST-DBP-021 - Hardcoded Timeout
- ST-DBP-023 - Empty Workflow
- ST-DBP-024 - Persistence Activity Check
- ST-DBP-025 - Variables Serialization Prerequisite
- ST-DBP-026 - Delay Activity Usage
- ST-DBP-027 - Persistence Best Practice
- ST-DBP-028 - Arguments Serialization Prerequisite
- ST-USG-005 - Hardcoded Activity Arguments
- ST-USG-009 - Unused Variables
- ST-USG-010 - Unused Dependencies
- ST-USG-014 - Package Restrictions
- ST-USG-017 - Invalid parameter modifier
- ST-USG-020 - Minimum Log Messages
- ST-USG-024 - Unused Saved for Later
- ST-USG-025 - Saved Value Misuse
- ST-USG-026 - Activity Restrictions
- ST-USG-027 - Required Packages
- ST-USG-028 - Restrict Invoke File Templates
- ST-USG-032 - Required Tags
- ST-USG-034 - Automation Hub URL
- Variables
- Arguments
- Imported Namespaces
- Coded automations
- Introduction
- Registering custom services
- Before and After contexts
- Generating code
- Generating coded test case from manual test cases
- Trigger-based Attended Automation
- Recording
- UI Elements
- Selectors
- Object Repository
- Data Scraping
- Image and Text Automation
- Citrix Technologies Automation
- RDP Automation
- VMware Horizon Automation
- Salesforce Automation
- SAP Automation
- macOS UI Automation
- The ScreenScrapeJavaSupport Tool
- The WebDriver Protocol
- Extensions
- About extensions
- SetupExtensions tool
- UiPathRemoteRuntime.exe is not running in the remote session
- UiPath Remote Runtime blocks Citrix session from being closed
- UiPath Remote Runtime causes memory leak
- UiPath.UIAutomation.Activities package and UiPath Remote Runtime versions mismatch
- The required UiPath extension is not installed on the remote machine
- Screen resolution settings
- Group Policies
- Cannot communicate with the browser
- Chrome extension is removed automatically
- The extension may have been corrupted
- Check if the extension for Chrome is installed and enabled
- Check if ChromeNativeMessaging.exe is running
- Check if ComSpec variable is defined correctly
- Enable access to file URLs and Incognito mode
- Multiple browser profiles
- Group Policy conflict
- Known issues specific to MV3 extensions
- List of extensions for Chrome
- Chrome Extension on Mac
- Group Policies
- Cannot communicate with the browser
- Edge extension is removed automatically
- The extension may have been corrupted
- Check if the Extension for Microsoft Edge is installed and enabled
- Check if ChromeNativeMessaging.exe is running
- Check if ComSpec variable is defined correctly
- Enable access to file URLs and InPrivate mode
- Multiple browser profiles
- Group Policy conflict
- Known issues specific to MV3 extensions
- List of extensions for Edge
- Extension for Safari
- Extension for VMware Horizon
- Extension for Amazon WorkSpaces
- SAP Solution Manager plugin
- Excel Add-in
- Test Suite - Studio
- Troubleshooting
Studio User Guide
Configuring Activity Project Settings
Activity Project Settings represent a set of changes that can be configured at the project level and applied to all activities part of project dependencies.
To configure activity properties at project level click the icon in the Project panel. The Project Settings window opens:
Tabs under Activity Settings contain the settings available for each installed activity package and for some bundled dependencies like Computer Vision, part of UIAutomation.
These settings can be configured for two scenarios: Run and Debug. In this way, for the same activities in the project, specific settings are applied when the project is run, while a different set of settings are applied during debugging.
BrowserType
property with the IE
default browser for opening the URL. If in Activity Project Settings, the same property is set to open URLs in Firefox, then this setting overwrites defaults and applies to all activities with
this property used in the project.
BrowserType
property set to Chrome in its Properties panel, then the value set in the panel overwrites any other value configured in the Activity Project Settings window.
A set of actions are available in the Bulk Action drop-down menu for performing changes to multiple settings:
- Reset all
- Reset run settings
- Reset debug settings
- Copy debug settings to run
- Copy run settings to debug.
Please bear in mind that even though activity properties are changed from the Property Settings window and new values are applied throughout the project, the default values in the Properties panel are not visibly updated. The change is applied, but not visible in the Properties panel.
The configured activity settings are saved in the project location, and are visible in the Project panel, under the .settings folder.
To save your Activity Project Settings configuration and apply it to other future automation projects use the Save as Template functionality in Studio.
To find out more about the settings available for various package, Project Settings pages are available in the Activities guide for the packages that support this feature, for example, Project Settings for UI Automation Modern.