- Release Notes
- Getting Started
- Setup and Configuration
- Automation Projects
- Dependencies
- Types of Workflows
- File Comparison
- Automation Best Practices
- Source Control Integration
- Debugging
- The Diagnostic Tool
- Workflow Analyzer
- About Workflow Analyzer
- ST-NMG-001 - Variables Naming Convention
- ST-NMG-002 - Arguments Naming Convention
- ST-NMG-004 - Display Name Duplication
- ST-NMG-005 - Variable Overrides Variable
- ST-NMG-006 - Variable Overrides Argument
- ST-NMG-008 - Variable Length Exceeded
- ST-NMG-009 - Prefix Datatable Variables
- ST-NMG-011 - Prefix Datatable Arguments
- ST-NMG-012 - Argument Default Values
- ST-NMG-016 - Argument Length Exceeded
- ST-DBP-002 - High Arguments Count
- ST-DBP-003 - Empty Catch Block
- ST-DBP-007 - Multiple Flowchart Layers
- ST-DBP-020 - Undefined Output Properties
- ST-DBP-023 - Empty Workflow
- ST-DBP-024 - Persistence Activity Check
- ST-DBP-025 - Variables Serialization Prerequisite
- ST-DBP-026 - Delay Activity Usage
- ST-DBP-027 - Persistence Best Practice
- ST-DBP-028 - Arguments Serialization Prerequisite
- Variables
- Arguments
- Imported Namespaces
- Recording
- UI Elements
- Control Flow
- Selectors
- Object Repository
- Data Scraping
- Image and Text Automation
- Automating Citrix Technologies
- RDP Automation
- SAP Automation
- VMware Horizon Automation
- Logging
- The ScaleCoordinates Migration Tool
- The ScreenScrapeJavaSupport Tool
- The WebDriver Protocol
- StudioPro
- Extensions
- Troubleshooting
Studio User Guide
Microsoft Edge Extension Troubleshooting
This page presents the most frequent reasons for which the UiPath Extension for Microsoft Edge might not work properly, and how to solve these issues.
ChromeNativeMessaging.exe
enables communication between the UiPath Extension for Edge and the UiPath Studio/Robot.
- Open Microsoft Edge.
- Open Task Manager.
-
Check if the
ChromeNativeMessaging.exe
process is running. -
If the process is not running:
ComSpec
environment variable is missing or has an invalid value, then Microsoft Edge cannot launch the ChromeNativeMessaging.exe
.
ComSpec
environment variable.
%SystemRoot%\system32\cmd.exe
.
By default, the extension is not granted access to File URLs or InPrivate mode. To enable these:
- In Microsoft Edge, navigate to
edge://extensions/
. The Microsoft Edge Extensions page is displayed. - Navigate to the UiPath extension and click Details . The UiPath Web Automation details page is displayed.
- Make sure the Allow in InPrivate and Allow access to file URLs options are selected.
UiPath Extension for Microsoft Edge does not support automating multiple browser instances running with multiple user profiles at the same time. Therefore, browser automation requires you to close all active instances of Microsoft Edge and restart the browser using a single user profile.
In some cases, Microsoft Edge background processes prevent it from closing completely, which interferes with automations even if the browser instance is not visible.
We recommend closing Microsoft Edge by right-clicking the Microsoft Edge icon in the System Tray, and selecting Close Microsoft Edge. This ensures that no other user profiles remain in use in the background.
Simulate
input method no longer works on HTML elements that have a click handler with javascript:
URI.
In this case, the simulated click will not take effect and no errors will reported.
This was reported as a Chromium bug here: https://bugs.chromium.org/p/chromium/issues/detail?id=1299742 This issue is quite rare as very few HTML elements have click handlers in this form.
Workaround
Simulate
to any other input method:
- Chromium API
- Hardware Events
- Window Messages
The DeveloperToolsAvailability has the following possible values:
- 0 = Disallow usage of the Developer Tools on extensions installed by enterprise policy, allow usage of the Developer Tools in other contexts
- 1 = Allow usage of the Developer Tools
- 2 = Disallow usage of the Developer Tools
1
to enable the full functionality of the extension.
This value is automatically set correctly when the extension is installed but it will be overwritten if your system administrator has set another value for this policy.
The other values for DeveloperToolsAvailability cause the problems listed below.
0
then:
- The UiPath Extension for Edge will be restricting to working with LTS versions of UiAutomation (19.10.x, 20.10.x, 21.10.x, 22.4.x)
- The
InjectJS
Activity will not work.
2
then:
- All the limitations from
DeveloperToolsAvailability=0
apply - The
ChromiumAPI
input method will not work.
ChromeNativeMessaging.exe
could not be started:
Cannot communicate with UiPath Platform
The native part of the extension is not configured correctly.
Re-install the extension from UiPath Studio.
For MV3 extensions, the browser loads the extension later, after the web pages have loaded. This means that on slower machines, the Open Browser activity from UiPath.UiAutomation.Activities version 20.10 or older can reach the internal timeout of 20 seconds before the extension has started.
Starting with v20.10.13, the internal timeout for the Open Browser activity has been increased from 20 seconds to 60 seconds.
UIPATH_OPEN_BROWSER_TIMEOUT_SECONDS
environment variable. For
example, set UIPATH_OPEN_BROWSER_TIMEOUT_SECONDS=120
to use 120
seconds for the activity's timeout.
- Check if the Extension for Microsoft Edge is installed and enabled
- Check If ChromeNativeMessaging.exe Is Running
- Check if ComSpec variable is defined correctly
- Enable access to file URLs and InPrivate mode
- Multiple browser profiles
- Multiple Microsoft Edge instances with multiple user profiles
- Stopping all Microsoft Edge instances
- Known Issues Specific to MV3 Extensions
- Click activity with Simulate fails on specific web page elements
- The DeveloperToolsAvailability Group Policy value must be set to 1
- The UiPath Web Automation browser window shows a warning
- Open Browser activity has an insufficient timeout