Robot admin guide
Licensing troubleshooting
Error message: Robot does not exist.
Connection status: Connected but unable to retrieve a license.
Potential issue: This error code can appear when 2023.10 and newer robots are connected to Orchestrator 2023.4 and older. The cause of this error could be linked to error codes 1232, 1247, or 1420. For more information, see the solution for error codes 1232, 1247, or 1420.
Error message: The standard machine does not have an exact match to the name of the machine the robot is installed on.
Connection status: Connected but identified configuration issues.
Potential issue: The machine key used to connect the robot to Orchestrator is configured to work with a different standard machine.
Solution: Check the specific information for the machine configuration in Orchestrator.
Error message: No robot configured for the current user.
Connection status: Connected but unable to retrieve a license.
Potential issue: There is no robot configured for the user that attempted to connect to Orchestrator.
Solution: Make sure that the user that tries to connect to Orchestrator has a robot configured and tied to its account.
Error message: Could not find unattended robot for user key {0}.
Connection status: Connected but unable to retrieve a license.
Potential issue: There are insufficient attended licenses, and the robot switches to unattended licenses.
Solution: Create a new unattended robot or re-enable the existing one, if disabled.
This error may occur just before Error 191x appears.
Error message: Could not find robot by key {0}.
Connection status: Connected but unable to retrieve a license.
Potential issue: The robot user is disabled in Orchestrator, so the corresponding Client Credentials are no longer valid.
Solution: Create a new robot or re-enable the existing one, if disabled, then restart the robot instance on the machine.
Error message: No runtime licenses available.
Connection status: Connected as Unattended.
Potential issue: The user is connected to Orchestrator, but does not have unattended runtimes.
Solution: Allocate unattended licenses for the robot machine from Orchestrator: Tenant > Machines > Runtime details > Production (Unattended).
Error message: The domain/username configured in Orchestrator does not match any user on the machine.
Connection status: Connected but identified configuration issues.
Potential issues:
-
使用计算机密钥或客户端 ID/客户端密码进行连接,并且 Orchestrator 中的 Unattended Robot 凭据与计算机上的任何用户都不匹配。
-
The user does not use a specific Windows user account.
Solution: Check the specific information for the user in Orchestrator: Tenant > Manage Access > Edit user > Unattended setup > Domain/Username.
Error message: Invalid authentication token.
Connection status: Connected but unable to retrieve a license.
Potential issue: The authentication token used to maintain the connection to Orchestrator has expired or is no longer valid.
-
Check if the robot configuration in Orchestrator is correct and an attended license is available.
-
通过计算机密钥或交互式登录断开与 Orchestrator 的连接,然后重新连接。
Error message: No more <License Name> robots available.
Connection status: Connected but unable to retrieve a license.
Potential issue: The Orchestrator tenant to which the robot is connected does not have any available licenses for the requested type. This can occur when multiple robots share a single license.
Solution: Verify the license allocation from the admin panel in Automation Cloud.
Error message: Update Failed: Please Disconnect Some Machines To Match The Number Of Defined Licenses.
Connection status: -
Potential issue: There is a mismatch between the updated license and the license Orchestrator expects. For example, upon updating the license, from a total of ten runtimes in the license, the user transfers five from Unattended to Citizen Developer. However, Orchestrator expects 10 available runtimes, and thus, this error occurs.
解决方案:
-
Remove the existing license, select the Activate Online option, then provide the license code again.
-
Remove the unattended robot from the Robots page in Orchestrator, then on the Licenses page in Orchestrator, select the Update option. This updates all runtimes.
Error message: Please remove some Development Robots to match the number of defined licenses.
Connection status: -
Potential issue: This error occurs when updating the license, if the number of the available runtimes does not match the active runtimes.
Solution: Remove the active runtimes from their users, update the license, then allocate runtimes back to users, based on the updated license offer.
This error code applies to connections to Automation Suite Orchestrator.
Error message: Action not possible. Valid license is required!
Connection status: Connected but unable to retrieve a license.
Potential issue: The Orchestrator tenant to which the robot is connected does not have any available licenses.
Solution: Make sure that the tenant has enough licenses. Licenses can be assigned by accessing Admin > Tenants > Edit license allocation.
此错误代码适用于服务 URL 连接。
Error message: There are no available licenses on the server.
Connection status: Connected but unable to retrieve a license.
-
机器人连接到的 Orchestrator 租户没有任何可用许可证。
-
用户仅分配有 Unattended 许可证,并使用交互式登录连接到 Orchestrator,这取决于 Attended 许可证。
-
用户仅分配有一个许可证,并且正在使用两台不同的计算机。
-
Make sure that the tenant has enough licenses. Licenses can be assigned by accessing Orchestrator: Admin > Tenants > Edit license allocation.
-
请改用计算机密钥:确保在 Orchestrator 中正确定义所有要求。
-
If the user already has an attended license assigned, make sure Enable user to run automations option is enabled.
-
要在两台计算机上使用单个许可证,必须先断开第一台计算机的连接,然后再连接第二台计算机。
此错误代码适用于计算机密钥连接。
Error message: There are no available licenses on the server.
Connection status: Connected but unable to retrieve a license.
-
机器人连接到的 Orchestrator 租户没有任何可用许可证。
-
用户仅分配有一个许可证,并且正在使用两台不同的计算机。
-
Make sure that the tenant has enough licenses. Licenses can be assigned by accessing Orchestrator: Admin > Tenants > Edit license allocation.
-
要在两台计算机上使用单个许可证,必须先断开第一台计算机的连接,然后再连接第二台计算机。
Error message: Cannot acquire licenses because the machine licensing is turned off.
Connection status: Connected, unlicensed.
Potential issue: The machine used to connect the Robot to Orchestrator is disabled.
Solution: Enable the machine used to authenticate the Robot against Orchestrator, as described in Enabling/Disabling a Machine.
Connection status: -
Potential issue: This license has been restricted due to Export Control Restrictions.
Solution: Revisit the rules for export control. If the problem persists, reach out to support.