activities
latest
false
UiPath logo, featuring letters U and I in white

UI Automation Activities

Last updated Dec 4, 2024

Set Text

UiPath.UIAutomationNext.Activities.NSetText

Description

Enters text in a specified UI element, for example a text box.

This activity can be used both inside and outside a Use Application/Browser activity.

This activity is compatible with Object Repository.

Project compatibility

Windows - Legacy | Windows

Windows - Legacy, Windows configuration

Designer panel
  • Click Indicate in App/Browser to indicate the UI element to use as target.

    After you indicate the target, select the Menu button to access the following options:

    • Indicate target on screen - Indicate the target again.
    • Edit target - Open the selection mode to configure the target.
    • Remove informative screenshot - Remove the screenshot of the target application or web page.
    • Add to Object Repository - Add the current UI element to a library project, from where it can be reused throughout your automation process.
  • Text - The string to be written in the text attribute of the target element.

Properties panel

Common

  • Continue on error - Specifies if the automation should continue even when the activity throws an error. This field only supports Boolean values (True, False). The default value is False. As a result, if the field is blank and an error is thrown, the execution of the project stops. If the value is set to True, the execution of the project continues regardless of any error.
  • Delay after - Delay (in seconds) between the time this activity is completed and the time the next activity begins any operations. The default value is 0.3 seconds. Adding a delay between activities ensures that one activity has enough time to complete before the next activity begins.

    When used within a Trigger Scope activity or within a triggered workflow, it is recommended to set the value to 0.

  • Delay before - Delay (in seconds) between the time the previous activity is completed and the time this activity begins performing any operations. The default value is 0.2 seconds. Adding a delay between activities ensures that one activity has enough time to complete before the next activity begins.

    When used within a Trigger Scope activity or within a triggered workflow, it is recommended to set the value to 0.

  • Display name - The name displayed for the activity in the Designer panel. A display name is automatically generated when you indicate a target.

  • Timeout - Specify the amount of time (in seconds) to wait for the activity to be executed before throwing an error. The default value is 30 seconds.

Input

  • Target - The target element. Target element must be set. Before indicating on screen, this field is set to (null). Once the target is indicated, all properties regarding the element that was indicated are displayed.
    • CV Control type - Indicates the type of control identified using Computer Vision.
    • CV Text - Indicates the text identified using Computer Vision.
    • Fuzzy selector - The parameters for the fuzzy selector.
    • Native text - The text that is used to identify the UI element.
    • Responsive websites - Enable responsive websites layout.
    • Strict selector - The strict selector generated for the UI element.
    • Targeting methods - The selector types that you want to use for identifying the element. This property can be set to any combination from the drop-down menu:
      • None
      • Strict selector
      • Fuzzy selector
      • Image
      • Native text
      • Computer Vision - To use Computer Vision as a targeting method, you need to go to Project Settings > Computer Vision and make sure to set the correct server endpoint. You can leave this field as it is and use UiPath Cloud, which is filled-in by default, or you can enter another value either by selecting any of the other public endpoints specific to a server region or your own on-premises server.

        Another way of using Computer Vision as a targeting method is to set Use Local Server to True. This implies that the UiPath.ComputerVision.LocalServer package is installed in your project. When Local Server is enabled, the server value is over-written. However, the Local Server is not available in cross-platform projects.

    • Visibility check - Checks whether the UI element is visible or not. You can choose one of three options from the drop-down menu:
      • None - Does not check for visibility.
      • Interactive (for Fuzzy Selector) - Default option. Checks if the element is potentially visible, ignoring page scroll and obstructions by other apps, or the fact that the application is minimized. This check is useful when trying to ensure that you are not targeting invisible elements that exist in the DOM but are hidden.
      • Fully visible - Checks if the UI element is visible or not.
    • Wait for page load - Before performing the action, wait for the application to become ready to accept input. You can choose one of three options from the drop-down menu:
      • None - Does not wait for the target to be ready.
      • Interactive - Waits until only a part of the app is loaded.
      • Complete - Waits for the entire app to be loaded.
    • Window selector (Application instance) - The selector that is used for the application window. Only applicable when the window attach mode is set to Application instance.
  • Text - See Text in the Designer panel.

Input/Output Element

  • Input element - The UI element on which the activity is executed, stored in an UIElement object. This field supports only UIElement objects. This object can be obtained from the Output Element property field of other UI Automation activities.
  • Output element - Outputs a target UI Element and stores it in a UIElement object, which can be further used to target the same element with other activities.

Misc

  • Private - If selected, the values of variables and arguments are no longer logged at Verbose level. This field supports only Boolean (True, False) values. The default value is False.

Options

  • Alter disabled element - If selected, the activity executes the action even if the specified UI element is disabled. This field only supports Boolean values (True, False). The default value is False.
  • Cache target element - Cache the target element when found and reuse it in the next activity run to improve the execution performance. This field supports only Boolean (True, False) values. The default value is False. When used within a Trigger Scope activity or within a triggered workflow, it is recommended to set the value to True.
  • Description
  • Project compatibility
  • Windows - Legacy, Windows configuration

Was this page helpful?

Get The Help You Need
Learning RPA - Automation Courses
UiPath Community Forum
Uipath Logo White
Trust and Security
© 2005-2024 UiPath. All rights reserved.