2023.4.2
Release date: 1 September 2023
We have released a new version of the UiPath.OrganizationMigrationApp tool so that you can easily migrate from a standalone UiPath® product to Automation Suite. For details, see Migration prerequisites.
Release date: 10 August 2023
This release only brings security updates and patches to address Common Vulnerabilities and Exposures (CVEs).
-
Erratum - added October 17, 2024
In a proxy environment, if the proxy server uses the same port as the TCP port of any other service in the Istio service mesh, such as port 8080, pods cannot communicate with the FQDN. The issue causes the following error:System.Net.Http.HttpRequestException: The proxy tunnel request to proxy 'http://<proxyFQDN>:8080/' failed with status code '404'.
System.Net.Http.HttpRequestException: The proxy tunnel request to proxy 'http://<proxyFQDN>:8080/' failed with status code '404'.To fix the issue, see Automation Suite on EKS/AKS troubleshooting.
-
Erratum - added August 14, 2024
For AI Center and Task Mining, theListBucket API
prerequisite check fails when using an external objectstore. However, AI Center and Task Mining do not use theListBucket API
permission. We removed the unnecessary check in Automation Suite 2023.4.8. -
Erratum - added June 25, 2024
Following an Automation Suite on AKS installation or upgrade, the backup setup does not work because of a failure to connect to Azure Government. You can fix the issue by taking the steps described in Automation Suite on EKS/AKS troubleshooting.
-
Erratum: Added April 19, 2024
An upgrade known issue affecting AKS causes Automation Suite to fail. When trying to upgrade AKS, theargocd-redis-ha-server
pod is put in error state. If you encounter this issue, use the workaround documented in the Troubleshooting chapter. The issue no longer occurs in Automation Suite 2023.4.6. -
Erratum: Added November 6, 2023
In versions 2023.4.0 through 2023.4.2, if you have an Active Directory (AD) integrated environment, you will see sporadic failures from the product leading to the IIS application pool restarting. This issue has been fixed in version 2023.4.3, but it still affects the aforementioned versions. As such, if you use AD, we highly recommend that you directly install or upgrade to 2023.4.3. Otherwise, you will encounter functionality issues.
To find out what has changed on each Automation Suite product, visit the following links.
If the product is greyed out, this new Automation Suite version does not bring any changes to it.
For the Kubernetes versions that each Automation Suite version supports, see Kubernetes compatibility.
This Automation Suite release bundles the following internal components:
Component |
Version |
---|---|
Istio | 1.17.2 (Distroless) |
ArgoCD | v2.5.10 |
Prometheus | v2.39.1 |
Grafana | 9.5.2 |
Fluentd & Fluent-bit |
logging-operator : 4.1.0 logging-operator-logging : 4.1.0 |
Gatekeeper | 3.11.0 |
Cert-Manager | v1.11.2 |
Velero | 3.1.6 |
The migration tool version you need depends on the standalone products you plan to migrate and the targeted Automation Suite version. For more details, see Migration compatibility matrix.
For instructions on migrating a standalone product to the current version of Automation Suite, see Full migration.