2022.4.7
发行日期:2023 年 6 月 13 日
改进了独立版到 Automation Suite 的迁移
发行日期:2023 年 6 月 27 日
如果您正在考虑从独立的 UiPath™ 产品迁移到 Automation Suite,有一个好消息要告诉您:我们改进了该流程。现在该流程不仅更加简单,而且涵盖了更多场景。
While the single-tenant migration continues to be the same as before, the full migration operation now relies on an improved migration tool and supports the following scenarios:
- 将独立产品迁移到新的 Automation Suite 安装。这意味着您尚未通过 Automation Suite 安装任何产品,并且您可以将独立产品迁移到新的 Automation Suite 实例。
- 将独立产品迁移到预先存在的 Automation Suite 安装。这意味着您之前通过 Automation Suite 安装的产品,现在想要迁移更多独立产品。
For extensive documentation, see Full migration.
原始设备上的 Ceph
勘误表:2023 年 6 月 21 日
We have moved the Objectstore outside the block storage and directly attached it to the nodes' disk. We have decided to implement this change so that we can reduce the replication factor for storage from 18x to 3x. While previously you needed 18 GiB of data disk to store 1 GiB of data, you now need only 3 GiB of disks. To find out more about this, check out the Hardware and software requirements and Evaluating your storage needs.
此方法的另一个显着优势是,您只需添加新磁盘即可扩展存储,而无需增加服务器节点的数量或更改任何其他配置。
错误修复
- 当由于存储桶所有权从一个用户更改为另一个用户而导致凭据管理器失败时,我们将尝试更改所有权。以前,我们尝试创建具有相同名称的存储桶,这会导致升级问题。
已知问题
-
勘误 - 于 2024 年 10 月 17 日添加:在代理环境中,如果代理服务器使用与 Istio 服务网格中任何其他服务的 TCP 端口相同的端口(例如端口 8080),则 Pod 无法与 FQDN 通信。该问题会导致以下错误:
System.Net.Http.HttpRequestException: The proxy tunnel request to proxy 'http://<proxyFQDN>:8080/' failed with status code '404'.System.Net.Http.HttpRequestException: The proxy tunnel request to proxy 'http://<proxyFQDN>:8080/' failed with status code '404'.要解决此问题,请参阅故障排除部分。
-
勘误 - 于 2024 年 8 月 29 日添加:我们发现了与 TLS 1.2 中使用弱密码相关的某些漏洞。有关如何缓解此问题的详细信息,请参阅如何解决 TLS 1.2 中的弱密码问题。
-
Erattum - added June 25, 2024: Occasionally, some API calls from Studio or Robot can fail with a 413 error code or a
RequestEntityTooLargeerror message. To fix the issue, see the Troubleshooting section. -
Erratum - added May 20, 2024: On single-node deployments with in-cluster storage, upgrades from version 2022.4.1 or older fail at the fabric stage due to a
rook-cephmigration issue. To prevent the issue, follow the instructions in this troubleshooting article: Single-node upgrade fails at the fabric stage. -
Erratum - added April 19, 2024: In certain situations, Prometheus pods can fail to start due to an out-of-memory (OOM) error. To fix the issue, see the Troubleshooting section.
-
Erratum - added April 19, 2024: Alert configurations (email and webhook receivers) get lost on reboot of machine or re-sync of
alertmanager-configsecret. For details, refer to -
勘误 - 于 2024 年 4 月 19 日添加:在某些情况下,监控仪表板中会缺少 Ceph 指标和警示。要解决此问题,请参阅故障排除部分。
-
Erratum - added April 19, 2024: False positive CephMgrIsAbsent alerts are displayed even though there are no storage issues.
-
勘误 - 于 2024 年 2 月 28 日添加:存储过程不支持 SQL Server 和 SQL 数据库之间的排序规则差异。为避免任何潜在问题,必须确保 SQL Server 和 SQL 数据库的排序规则设置相同。
-
Erratum - added January 2024: The replica cleanup script incorrectly reclaims storage on the nodes. For more details, see the Storage reclamation patch troubleshooting article.
-
勘误 - 于 2023 年 11 月 6 日添加
在版本 2023.4.0 到 2023.4.2 中,如果您有 Active Directory (AD) 集成环境,您会看到产品偶尔出现故障,导致 IIS 应用程序池重新启动。此问题已在版本 2023.4.3 中修复,但仍会影响上述版本。因此,如果您使用 AD,我们强烈建议您直接安装或升级到 2023.4.3。否则,您将遇到功能问题。
-
还原启用了 AI Center™ 的 Automation Suite 集群后,您必须确保服务令牌和集群凭据指向还原的集群。 有关更多信息,请查看故障排除页面中特定于 AI Center 的部分。
捆绑详情
产品版本
要了解每个 Automation Suite 产品的更改,请访问以下链接。
如果产品显示为灰色,则此 Automation Suite 新版本不会对其进行任何更改。
内部第三方组件版本
此 Automation Suite 版本捆绑了以下内部组件:
| 组件 | 版本 |
|---|---|
| RKE2 | v1.21.4+rke2r2 |
| ArgoCD | v2.2.5 |
| rook-ceph | v1.8.9 |
| 证书管理器 | 1.2.0 |
| Rancher | 2.6.0 |
| rancher-istio | 100.0.0-up1.10.4 |
| longhorn | 1.3.3 |
| longhorn-crd | 1.1.100 |
| 重新加载程序 | v0.0.89 |
| CSI 驱动程序 smb | v1.8.0 |
| rabbitmq 运算符 | 1.5.0 |
| redis 运算符 | 6.2.8-11 |
| redis 集群 | 6.2.8-53 |
| MongoDB | 4.4.4-ent |
| docker_registry | 2.7.1 |
| self_heal_operator | 0.0.1 |