セキュリティ オプションを設定する
The settings you specify here are inherited by all organizations in your installation as default, but organization administrators can overwrite these settings as needed at the level of the individual organization.
Orchestrator のインストールでセキュリティ オプションを設定するには、[管理] > [ユーザー] > [認証設定] に移動し、必要に応じて次のオプションを編集します。
パスワードの複雑さ
[パスワードの複雑さ] の設定を編集しても既存のパスワードには影響しません。
Field | Description |
---|---|
Special characters | Select to force users to include at least one special character in their password. By default, this checkbox is not selected. |
Lowercase characters | Select to force users to include at least one lowercase character in their password. By default, this checkbox is selected. |
Uppercase characters | Select to force users to include at least one uppercase character in their password. By default, this checkbox is not selected. |
Digits | Select to force users to include at least one digit in their password. By default, this checkbox is selected. |
Minimum password length | Specify the minimum number of characters a password should contain. By default, it is 8. You can set this value between 1 and 256 characters. |
Days before password expiration | Specify the number of days for which the password is available. After this period, the password expires and needs to be changed. The minimum accepted value is 0 (the password never expires), and the maximum is 1000 days. |
Number of times a password can be reused | The minimum accepted value is 0 (never allow reusing a password), while the maximum is 10. |
Change password on the first login | If set to Required, users that log in for the first time must change their password before being allowed to access Automation Suite. If set to Not required, users can log in and continue to use the admin-defined password until it expires. |
アカウント ロック
Field | Description |
---|---|
Enabled or Disabled toggle | If enabled, locks the account for a specific amount of seconds after a specific amount of failed login attempts. This also applies to the password change feature. |
Account lockout duration | The number of seconds a user needs to wait before being allowed to log in again after exceeding the Consecutive login attempts before lockout. The default value is 5 minutes. The minimum accepted value is 0 (no lockout duration), and the maximum is 2592000 (1 month). |
Consecutive login attempts before lockout | The number of failed login attempts allowed before the account is locked. The default value is 10 attempts. You can set a value between 2 and 10. |
4 か月前に更新