automation-suite
2024.10
true
UiPath logo, featuring letters U and I in white

Automation Suite on Linux Installation Guide

Last updated Jan 8, 2025

Performing an in-place upgrade

The Automation Suite in-place upgrade process allows you to move to a new Automation Suite version while keeping your settings and data intact on the same hardware.

  • In the in-place upgrade process, you first upgrade Kubernetes and other infrastructure components sequentially to the target version.

  • Following Kubernetes and other infrastructure component upgrades, you must uninstall the current version and install the target version of shared components and UiPath® products.

  • In case of hard failure beyond recovery during the upgrade process, you need to roll back to the previous version using the backup and restore capability.

Process overview

#

Upgrade process steps

1.

Prepare the upgrade:

  1. Download the installer file. See more...

  2. Regenerate the cluster_config.json file. See more...
  3. Perform various service-related configuration updates. See more...

  4. Configure the external registry or create a temporary registry. See more...

2.

Execute the upgrade:

  1. Configure and create the backup.See more...

  2. Running the prerequisite checks. See more...

  3. Put the cluster in maintenance mode. See more...

  4. Migrating Longhorn workloads to local PV, MongoDB data to SQL, and Ceph to Helm-based deployment. See more...

  5. Upgrade the infrastructure. See more...

  6. Install the services and shared components. See more...

3.

Note:

Not all post-upgrade steps are mandatory. Based on your upgrade scenario, you must take specific steps.

Post-upgrade steps:

Requirements

To perform an in-place upgrade, make sure you meet the following requirements:
  • You must meet the hardware and software requirements for the new Automation Suite version. If AI Center is enabled, make sure you meet the CUDA requirements.

  • You must ensure that the node has an additional capacity of 512 GiB to use as a backend for the registry. This is usually recommended to be on /uipath mount point.
  • Determine the supported versions for each upgrade scenario by checking the upgrade path matrix.

  • Download the required installer and bundle files.

  • If you use an in-cluster object store, you must have your cluster object store directly attached to the nodes' disk using Ceph on raw devices available in 2022.4.7, 2022.10, and 2023.4. For details, see Migrating objectstore from persistent volume to raw disks.

  • If you plan to upgrade from Automation Suite 2022.10 or earlier, and Process Mining is enabled, you must migrate process apps to the new process graph layout before starting the upgrade.

  • An additional disk is required to execute the AI Center training pipeline. Make sure that all the AI Center training pipelines are completed before the upgrade.

  • Process overview
  • Requirements

Was this page helpful?

Get The Help You Need
Learning RPA - Automation Courses
UiPath Community Forum
Uipath Logo White
Trust and Security
© 2005-2025 UiPath. All rights reserved.