UiPath Documentation
automation-suite
2024.10
false
Automation Suite on Linux installation guide

Optional: Increasing fault tolerance

Reference for increasing server node fault tolerance in the multi-node HA-ready production profile with in-cluster objectstore in Automation Suite.

This page is applicable only to the multi-node HA-ready production profile with in-cluster objectstore.

By default, the multi-node HA-ready production profile allows for one server node going down without causing a deployment failure. You can increase the tolerance to server node failure using the fault_tolerance parameter in the cluster_config.json file. The parameter modifies the replication factor of in-cluster storage components such as Ceph.

Hardware requirements​

To increase fault tolerance beyond 1, make sure your environment meets the following requirements:

  • Your cluster consists of a minimum of 2x+1 server nodes, where x is the required server node fault tolerance;
  • Each server node has raw device configured.

How to increase fault tolerance​

To increase fault tolerance beyond 1, take the following steps:

  1. Set fault_tolerance to the required value in the cluster_config.json file. If you set it before starting the installation or upgrade operation, you do not need to take any additional steps.

  2. Run the installer to complete the process from any of the server nodes:

    ./bin/uipathctl manifest apply /opt/UiPathAutomationSuite/cluster_config.json --versions versions/helm-charts.json
    ./bin/uipathctl manifest apply /opt/UiPathAutomationSuite/cluster_config.json --versions versions/helm-charts.json
    
  • Hardware requirements​
  • How to increase fault tolerance​

Was this page helpful?