- Automation Suite on Linux Release Notes
- Automation Suite on EKS/AKS Release Notes
- Automation Suite on OpenShift release notes
2.2510.1
2.2510.1 release notes for Automation Suite on Linux.
Release date: December 19, 2025
Support bundle command no longer requires configuration files
You can generate the support bundle using a simplified command. The paths to the configuration file (cluster_config.json) and the versions file (helm-charts.json) parameters are now optional.
For details, refer to Generating the support bundle.
Release date: March 25, 2026
Support for new RHEL version
We have expanded our OS support to include RHEL 9.7. For details on the supported RHEL versions, refer to RHEL compatibility matrix.
Release date: December 19, 2025
Bug fixes
- Erratum - added February 9, 2026: We fixed an issue where some Document Understanding microservices failed to start, particularly in IPv4-only environments.
- An issue was causing the Automation Suite upgrade to fail during image seeding due to an invalid reference to the
hashicorp/http-echo:1.0image. We have fixed the issue. - We have fixed an issue that prevented the
uipathctl rke2 gpu --enablecommand from deploying thenvidia-gpu-pluginDaemonSet pods on GPU nodes. This issue occurred in offline clusters with an in-cluster registry. - We have fixed an issue that caused the prerequisite checks to fail when Process Mining was enabled. The issue occurred due to the checks incorrectly treating
cert-manageras a required component, even though it is no longer needed for Process Mining. - An issue was causing upgrade operations to fail when the Kubernetes node hostname contained uppercase characters. The issue was due to the upgrade process relying on the system hostname, while Kubernetes automatically normalized the
kubernetes.io/hostnamelabel to lowercase. We have fixed the issue.
Known issues
Horizontal Pod Autoscaler and ArgoCD scaling conflict in HA environments
Erratum - added September 10, 2026: In HA environments, when load increases, the Horizontal Pod Autoscaler (HPA) scales the affected workloads up while the ArgoCD application controller scales them back down. This occurs due to ArgoCD treating the replica count defined in the Helm chart or manifest as the source of truth, causing the workloads to repeatedly scale up and down without stabilizing.
To address the issue, you must patch the argocd-cm ConfigMap in the <argocd> namespace so that ArgoCD ignores replica count differences:
kubectl -n <argocd> patch configmap argocd-cm --type merge -p \
'{"data":{"resource.customizations.ignoreDifferences.argoproj.io_Rollout":"jsonPointers:\n- /spec/replicas\n"}}'
kubectl -n <argocd> patch configmap argocd-cm --type merge -p \
'{"data":{"resource.customizations.ignoreDifferences.argoproj.io_Rollout":"jsonPointers:\n- /spec/replicas\n"}}'
Reapply the command after every ArgoCD chart re-sync or Automation Suite upgrade, since both overwrite the ConfigMap and remove the patch.
We fixed the issue in Automation Suite 2.2510.4.
Document Understanding CPU inference setting lost when upgrading to 2.2510.2 or later
Erratum - added September 10, 2026: If you enabled CPU inference for Document Understanding modern projects (enable_cpu_inference), the setting is not carried over when you upgrade to 2.2510.2 or later. This issue occurs due to a change in the expected location of the enable_cpu_inference parameter in cluster_config.json, starting with Automation Suite 2.2510.2.
Before upgrading to Automation Suite 2.2510.2 or later, move the enable_cpu_inference parameter from the documentunderstanding root to the modernProjects section:
// Before
"documentunderstanding": {
"enable_cpu_inference": false,
"modernProjects": {
"enabled": true
}
}
// Before
"documentunderstanding": {
"enable_cpu_inference": false,
"modernProjects": {
"enabled": true
}
}
// After (2.2510.2 or later)
"documentunderstanding": {
"modernProjects": {
"enabled": true,
"enable_cpu_inference": false
}
}
// After (2.2510.2 or later)
"documentunderstanding": {
"modernProjects": {
"enabled": true,
"enable_cpu_inference": false
}
}
Kerberos KDC discovery fails in Active/Active deployments due to truncated DNS SRV responses
Erratum - added September 10, 2026: In Automation Suite Active/Active deployments on Linux (RKE2), Kerberos KDC discovery can fail during installation or upgrade, resulting in Integrated Authentication and LDAP errors. The issue occurs because the Kubernetes DNS Service exposes DNS resolution over UDP/53 only. When a Kerberos SRV lookup, such as _kerberos._tcp or _kerberos._udp, returns a response too large for UDP, the DNS client retries over TCP/53. Since the Kubernetes DNS Service doesn't expose TCP/53, the retry fails.
To address the issue, enable TCP/53 on the Kubernetes DNS Service:
-
Edit the
rke2-corednsHelm chart configuration:kubectl -n kube-system edit helmchartconfig rke2-corednskubectl -n kube-system edit helmchartconfig rke2-coredns -
Under
zoneinspec.valuesContent, adduse_tcp: true:servers: - zones: - zone: . use_tcp: true port: 53servers: - zones: - zone: . use_tcp: true port: 53
We fixed the issue in Automation Suite 2.2510.4.
Studio Desktop cannot load Integration Service connectors and activities
Erratum - added July 23, 2026: In Studio Desktop, the Activities panel does not list Integration Service connectors and activities. The issue is caused by a routing misconfiguration in the intsvcs-periodic VirtualService.
To address the issue, refer to Studio Desktop cannot load Integration Service connectors and activities.
We fixed the issue in Automation Suite 2.2510.3.
Resizing a data disk partition requires the disk path even on subsequent runs
Erratum - added July 23, 2026: An issue prevents uipathctl from resizing an existing data disk partition (such as the Docker registry, monitoring, or Insights partitions) unless the underlying disk path is explicitly provided using the --volume flag. This behavior is incorrect, since uipathctl is designed to automatically detect the associated disk on subsequent runs without requiring --volume.
This issue is fixed in Automation Suite 2.2510.3.
Support bundle daemon sets are not cleaned up after collection
Erratum - added July 23, 2026: An issue prevents the support bundle daemon sets from being cleaned up on each node after a support bundle collection request finishes.
Before triggering a new support bundle request, delete the existing support bundle daemon set:
kubectl -n kube-system delete daemonset/support-bundle-daemon --ignore-not-found
kubectl -n kube-system delete daemonset/support-bundle-daemon --ignore-not-found
This issue is fixed in Automation Suite 2.2510.2.
Monitoring configuration updates do not take effect
Erratum - added July 23, 2026: An issue prevents the monitoring section parameters in cluster_config.json from being applied to the monitoring stack.
This issue is fixed in Automation Suite 2.2510.3.
Prerequisite checks fail when Document Understanding modern projects is enabled and AI Center is disabled
Erratum - added July 23, 2026: An issue causes the prerequisite checks command to incorrectly fail when Document Understanding modern projects is enabled and AI Center is disabled.
To address the issue, refer to Troubleshooting.
This issue is fixed in Automation Suite 2.2510.3.
Custom database names not supported for Solutions
Erratum - added April 15, 2026: An issue prevents you from using a custom database name for Solutions. If you specify a custom database name, the prerequisite checks fail.
To address this issue, you must use AutomationSuite_AutomationSolutions as the Solutions database name.
This issue is fixed in Automation Suite 2.2510.2.
Fluentd does not export logs in IPv6 environments
Erratum - added April 15, 2026: In IPv6 environments, Fluentbit fails to forward logs to Fluentd because the Fluentd forward input plugin binds to an IPv4 address by default.
To address this issue, you must patch the logging ArgoCD Application and set logging-operator.logging.fluentd.forwardInputConfig.bind to ::. For details, refer to the Troubleshooting section.
FQDN update fails in IPv6 and dual-stack environments
Erratum - added April 15, 2026: In IPv6 and dual-stack environments, FQDN updates fail at both the infrastructure level and the service level.
We fixed the issue in Automation Suite 2.2510.2.
AI Center and Document Understanding pods fail to start with TLS certificate verification enabled
Erratum - added April 15, 2026: When database TLS certificate verification is enabled, some AI Center and Document Understanding pods may get stuck in Init:CrashLoopBackOff. The await-migration-completion init container fails to connect to the database, with TLS/SSL handshake errors in the logs.
To address the issue, refer to AI Center and Document Understanding pods fail to start with TLS certificate verification enabled.
We fixed the issue in Automation Suite 2.2510.2.
Prerequisite check incorrectly validates monitoring and logging components
Erratum - added April 15, 2026: The prerequisite check incorrectly validates monitoring and logging components. Since these components are installed after the prerequisite phase, this validation is not necessary.
We fixed the issue in Automation Suite 2.2510.2.
Alertmanager sync failure in ArgoCD
Erratum - added March 18, 2026: Alertmanager may fail to sync in ArgoCD due to an invalid character in the alertmanager image tag.
To address this issue, update the Helm values under ArgoCD Parameters as follows:
kube-prometheus-stack:
alertmanager:
alertmanagerSpec:
version: v0.29.0
kube-prometheus-stack:
alertmanager:
alertmanagerSpec:
version: v0.29.0
We fixed the issue in Automation Suite 2.2510.2.
Insights real-time monitoring not working on the secondary cluster in Active/Active deployments
Erratum - added April 15, 2026: In Active/Active deployments with Insights real-time monitoring enabled, Orchestrator and platform services on the secondary cluster do not push real-time monitoring data due to configuration issues with call redirection from the secondary cluster to the primary cluster.
We fixed the issue in Automation Suite 2.2510.2.
Custom platform database name not supported when installing Process Mining
Erratum - added March 26, 2026: When Process Mining is enabled, using a custom platform database name causes the OMS backfill job to fail.
As a workaround, use AutomationSuite_Platform as the platform database name when installing Process Mining.
This issue will be fixed in Automation Suite 2.2510.2.
FIPS 140-2 support limitations
Erratum - added January 22, 2026: Insights and Integration Service are not supported on Automation Suite deployments that run on FIPS 140-2-enabled machines. To remain compliant with FIPS 140-2 requirements, you must disable these services.
For details, refer to Security and compliance.
Kerberos authentication limitations
Kerberos-based authentication is currently not supported for Integration Service.
We are working on bringing Kerberos support to upcoming Automation Suite releases.
Meanwhile, you can use alternative authentication mechanisms such as basic authentication or workload identity-based authentication.
Deprecation timeline
We recommend that you regularly check the deprecation timeline for any updates regarding features that will be deprecated and removed.
Bundling details
Product versions
The following table outlines the release status, version, and release notes for all UiPath products deployed under Automation Suite 2.2510.1.
Legend:
✅ New: This Automation Suite version includes a new product version. New release notes are available.
◆ Bundled: This flavor includes a previously released product version. No new release notes are available.
| Product | Version | Release notes |
|---|---|---|
| Action Center | ✅ New: 2.2510.1 | Action Center release notes |
| AI Center | ✅ New: 2.2510.1 | AI Center release notes |
| AI Computer Vision | ✅ New: 2.2510.1 | AI Computer Vision release notes |
| Apps | ✅ New: 2.2510.1 | Apps release notes |
| Automation Hub | ✅ New: 2.2510.1 | Automation Hub release notes |
| Automation Ops | ✅ New: 2.2510.1 | Automation Ops release notes |
| Data Service | ✅ New: 2.2510.1 | Data Service release notes |
| Document Understanding | ✅ New: 2.2510.1 | Document Understanding AI Center-based projects release notes Document Understanding modern projects release notes |
| Insights | ✅ New: 2.2510.1 | Insights release notes |
| Integration Service | ✅ New: 2.2510.1 | Integration Service release notes |
| Solutions | ✅ New: 2.2510.1 | Solutions release notes |
| Orchestrator | ✅ New: 2.2510.1 | Orchestrator release notes |
| Process Mining | ✅ New: 2.2510.1 | Process Mining release notes |
| Test Manager | ✅ New: 2.2510.1 | Test Manager release notes |
Internal third-party component versions
This Automation Suite release bundles the following internal components:
| Component | Version |
|---|---|
| RKE2 | 1.34.1+rke2r1 |
| ArgoCD | 3.2.0 |
| gatekeeper | 3.20.1 |
| rook | 1.17.6 |
| ceph | 19.2.3 |
| prometheus-pushgateway | v3.4.2 |
| cert-manager | v1.19.1 |
| kube-logging/logging-operator | 6.0.3 |
| kube-logging/config-reloader | 6.0.3 |
| istio | 1.28.0 |
| velero | 1.16.2 |
| reloader | 2.2.5 |
| Prometheus | 3.7.3 |
| Grafana | 12.2.1 |
| redis-operator | 8.0.2-2 |
| redis-cluster | 8.0.2-17 |
| oauth2-proxy | 7.13.0 |
- Support bundle command no longer requires configuration files
- Support for new RHEL version
- Bug fixes
- Known issues
- Horizontal Pod Autoscaler and ArgoCD scaling conflict in HA environments
- Document Understanding CPU inference setting lost when upgrading to 2.2510.2 or later
- Kerberos KDC discovery fails in Active/Active deployments due to truncated DNS SRV responses
- Studio Desktop cannot load Integration Service connectors and activities
- Resizing a data disk partition requires the disk path even on subsequent runs
- Support bundle daemon sets are not cleaned up after collection
- Monitoring configuration updates do not take effect
- Prerequisite checks fail when Document Understanding modern projects is enabled and AI Center is disabled
- Custom database names not supported for Solutions
- Fluentd does not export logs in IPv6 environments
- FQDN update fails in IPv6 and dual-stack environments
- AI Center and Document Understanding pods fail to start with TLS certificate verification enabled
- Prerequisite check incorrectly validates monitoring and logging components
- Alertmanager sync failure in ArgoCD
- Insights real-time monitoring not working on the secondary cluster in Active/Active deployments
- Custom platform database name not supported when installing Process Mining
- FIPS 140-2 support limitations
- Kerberos authentication limitations
- Deprecation timeline
- Bundling details
- Product versions
- Internal third-party component versions